Toll Free: (800) 927-7831
Phone: (360) 805-4930

The SASS 4100 Plus provides total sampling capability by combining Research International’s highly efficient, two-stage, dry filter-based aerosol collection device SASS 4100 with our SASS 3010 Particle Extractor. The system can be used for many applications requiring the collection and later analysis of airborne particulates, including:
Aerosol sample analysis is frequently plagued by three problems:
In response to these issues, Research International is now offering the SASS 4100, the highest-capacity portable aerosol dry collector in production.
The SASS 4100 continuously samples over 3500 liters/minute of ambient air as a primary air stream. Air flows radially inward into the concentrator through a coarse square-mesh screen. This inward radial flow provides 360 degree sampling of the surrounding aerosol environment. The primary fan and a curved air shroud are mounted above the sampler inlet section, channeling exhaust air into a vertical stream away from the inlet area.
Particulates in this air stream are transferred to a much smaller secondary air stream using patent-pending centrifugal and virtual impaction principles. Particles are routed into the secondary flow by forcing primary circuit air to circulate through specially shaped channels where centrifugal force and particle momentum isolate and concentrate the particles.
The secondary flow can reach aerosol concentrations that are 4X to 15X higher than present in the incoming air, yet the velocity of this secondary aerosol concentrate flow is much lower than peak velocities in the primary circuit. The two-stage sampler therefore amplifies and slows down the captured ambient aerosol particles prior to their collection. Due to advantageous pressure differentials within the device, one fan drives both the primary and secondary flows.
Particulates are collected from this concentrate by directing the secondary air through a disposable capture element (Figure 1). The filter is a 43 mm O.D. x 3 mm thick micro-fibrous electret ultrasonically bonded to a circular frame of 59 mm diameter and 5 mm thickness.
The fibrous media is up to 50X more efficient than a conventional glass or cellulosic material because each fiber incorporates a built-in electric field that captures particles using electrostatic dust precipitator principles, but at a microscopic level. The electret media is stable to 70°C, is virtually inert, and has high holding capacity due to a large internal surface-to-volume ratio.
The electret filter is mounted in a compact, easily disengaged holder located under the device’s baseplate.

SASS 4100 snap on electret filter.
The SASS 4100 has several favorable attributes:
A quick-release tripod, standard with the product, allows the circumferential sampling section to be located from about 0.6m to 1.43m above the tripod mounting surface.
The SASS® 3010 (Figure 2) manual extractor is used to extract and transfer into a small fluid volume, particulates captured by Research International’s electret filters. Captured particulates can be difficult to remove as the induced dipole fields that are responsible for their capture efficiency create a strong holding force that must be neutralized.
Once particulates have been released, they must then be removed from within the fibrous filter matrix and collected in a small amount of sample fluid. These processes are efficiently performed in a matter of 1 to 2 minutes using the SASS 3010 manual extractor.
Extraction efficiencies are typically in the range of 70 to 80%. To test extraction efficiency, a SASS 3100 and several electret filters were used to collect airborne fluorescent polystyrene beads of 1.8 microns diameter. Each filter was operated for a period of 10 minutes. After the collection phase was completed, the filters were mounted in a SASS 3010 and captured beads transferred to 5 ml of extraction buffer using the protocol outlined below. Extraction efficiencies were then determined using fluorometric assay methods.
It was found that an average recovery of 77% was achieved. A second extraction with an additional 5 ml of extraction fluid resulted in recovery of another 17% of the embedded beads, while two more 5 ml extractions resulted in small 4.5% and 1.5% additions to the total number of beads recovered, respectively.
| Characteristic | Description |
|---|---|
| Primary airflow: | 3600 liters/min is sampled uniformly from around the concentrator’s circumference. |
| Secondary airflow: | 265 LPM with the electret filter in place |
| Aerosol collection media | Fibrous electret bulk filter, RI part number 7100-134-230 |
| Air velocity at filter face | 2 m/sec. (43.4 mm diameter filter active area) |
| Filter mount | Hat-shaped fixture that locks onto the device’s baseplate |
| Overall size: | 38 cm high x 25.4 cm diameter max. |
| Weight: | 6.32 kg (13.9 lbs.) |
| Operating temperature range: | -40°C to 60°C |
| Ingress protection rating | 45 |
| Operating life | ECM fan rotor is only moving part. A bearing life of 30,000 hours is expected. |
| Power consumption | 90 watts. 100 to 230 VAC lump-in cord AD/DC converter supplied. If operated from DC, please specify DC source voltage of 12, 24 or 28 VDC. |
| Sound level: | 72 db-A @ 1 meter radius on inlet equatorial plane. |
| Mounting: | Quick-detach tripod legs; 0.53m to 1.46m adjustable height. |
| Accessories: | Hard shell carrying case. Electret sample filter assembly (for stand-alone operation). |
| Parameter | Value |
|---|---|
| Filter compatibility | For use with SASS 3100 and SASS 4100 electret filters |
| Extraction method | Acoustic vibration of the fluid-saturated filter is followed by pneumatic and mechanical counterflow-driven discharge of the suspended aerosol particles. |
| Extraction efficiency | 60-80% typical |
| Residue, run-to-run | 1.1% with dry wiping, and 0.01% to 0.1% with a 5 ml flush |
| Extraction time | 1 to 2 minutes, typical, with a flush cycle. |
| Extraction fluid | A pre-filled dropper bottle provides enough buffered extraction fluid to make a 5 ml sample. |
| Sample fluid storage | The extraction fluid bottle is also used for fluid sample storage upon extraction completion. |
| Physical size | • Body: 10.2 cm (W) x 13.4 cm (D) x 14.5 cm (H) • A 7.8 cm-high plunger protrudes from the extractor’s top surface. |
| Weight | 800 grams |
| Electrical power | Two size “D” primary batteries. |
| Operating temperature range | 0° C to 70° C |
