LaserWarn Open-Path Chemical Detection System

LaserWarn Open-Path Chemical Detection System - Indoor Model
The LaserWarn indoor model
LaserWarn is an open path chemical gas detection system based on patented quantum cascade laser technology. LaserWarn detects chemical threats over a coverage area of thousands of square meters, and is available in both indoor and outdoor versions.

Eye-safe laser beams and low-cost reflectors provide real-time, 24/7 early warning of Toxic Industrial Chemicals (TICs), Chemical Warfare Agents (CWAs), and other chemicals. The system configuration is tailored to each site, and can be visually blended into existing architecture and interior design. System updates can be provided in response to emerging threats.

LaserWarn Open-Path Chemical Detection System - Ourdoor Model
The LaserWarn outdoor model

Multiple hazardous chemicals can be detected within seconds, even in chemically "noisy" environments. The system requires no consumables, and is low maintenance compared to conventional networks of point sensors. The system is available in a ruggedized IP66-certified version for harsh environments, as well as a lighter version for indoor use.

The system features a multi-level graphical user interface, providing simple red/green information screens or more detailed with screens if preferred. Additionally, the XML data output streams directly into existing command & control displays.

DOWNLOAD DATA SHEET REQUEST QUOTE

Product Features
Typical Applications
Specifications: Indoor Model

LaserWarn Specifications - Indoor Model

Characteristic Description
Maximum Path Length 300 meters (one way)
Gases Detected Most Toxic Industrial Chemicals (TICs), Chemical Warfare Agents (CWAs) and other chemicals that are within the range of the system
Sensitivity Varies with gas and distance in path
Response Time Less than 5 seconds
Dimensions Approx. 18 x 14 x 7 inches
(46 x 35.5 x 18 cm)
Weight 32 lbs. (14.5 kg)
Electrical Power 110/220 VAC, 50/60 Hz, 100 Watts
Enclosure Type IP 20
Simultaneous Detection of Multiple Types of Gas Yes
Operating Temperature Range 10° C to 30° C
Installation Fixed position; portable configurations available as an option

Research International reserves the right to change specifications without prior notice.

Specifications: Outdoor Model

LaserWarn Specifications - Outdoor Model

Characteristic Description
Maximum Path Length 300 meters (one way)
Gases Detected Most Toxic Industrial Chemicals (TICs), Chemical Warfare Agents (CWAs) and other chemicals that are within the range of the system
Sensitivity Varies with gas and distance in path
Response Time Less than 5 seconds
Dimensions Approx. 41.5 x 19.2 X 11.5 inches
(105.5 x 49 x 29.5 cm)
Weight 125 lbs. (56.7 kg) for LaserWarn plus tip/tilt stage. 36 lbs. (16.3 kg) for electrical junction box with shroud.
Electrical Power 110/220 VAC, 50/60 Hz, 100 Watts
Enclosure Type IP 66
Simultaneous Detection of Multiple Types of Gas Yes
Operating Temperature Range -20° C to 60° C
Installation Fixed position

Research International reserves the right to change specifications without prior notice.

 
 
We Support What We Sell - 1-800-927-7831